12/14 Rev. 03 USER MANUAL Commissioning & Operation
64-xx
5
Printer connections
[7] Back of the 64-xx with the following options installed: USI board (H), connector for remote
operator panel (I) and start/stop signal input (J).
A Card slot
For SD/MMC cards; is not yet supported
B Card slot
For CompactFlash cards; used for storing fonts, logos, graphics, etc.
C USB interface type B (device)
For transfer of print data
D 2x USB interface type A (host)
To connect devices (e.g. keyboard, scanner)
E RS232 interface
For serial transfer of print data
F Status-LED/Ethernet
G Ethernet interface
To connect to an „Ethernet 10/100 Base T“ network
CAUTION!
Add-on devices of an inferior quality may damage the printer!
Connect the printer only to devices that fulfil SELV (safety extra-low volta-
ge) circuit requirements acc. to EN 60950!
Only connect OEM devices.