11/14 Rev. 03 USER MANUAL Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x
31
Testing the connection
1. Call the input window: Start > Programs > Accessories > Input prompt.
2. Enter the command „ping“ with the printers IP address, e.g. „ping 192.168.0.99“.
3. If the connection works properly, four answer lines appear in the input prompt win-
dow [19].
[19] Input prompt window after proceeding ping with the printers IP address.
As an additional test, „ping“ can also be called with the IP address of the access
point. The default IP address of the Netgear WG602 is 192.168.0.227
If the printer doesn´t send back an answer, the connection doesn´t work properly.
Measures in this case are:
Check all the above mentioned settings.
Contact the network administrator for advice.
Sending a printjob
1. Have an Easy-Plug printjob ready (in this example: „test.txt“).
2. Send the printjob using the command „lpr“ [20].
[20] Sending a printjob using the lpr command
After some seconds, the printer should start printing.
During data transmission, the LED at the WLAN CF card flashes.