03/13 Rev. 5.08-01 USER MANUAL Einrichten
64-xx – 64-xx dispenser
18
Information about operation with start signal can be found in topic section
Advanced Applications
, chapter „Printing with start signal“.
Parameter settings for „64-xx dispenser M“
The printing/dispensing process can be triggered by foot switch or by
light barrier:
Foot switch The values preset by the manufacturer (see tab. 3) are valid for manual
triggering of the printing/dispensing via the Single-Start connector, e.g.
using a foot switch. After pressing the foot switch, one label is printed and
dispensed.
Set
DISPENSER PARA > Start source to „Foot switch“.
Light barrier The dispensed label triggers a light barrier. This stops the printing/
dispensing until the user takes the label off. Then, the printer moves the
material back under the print head (only if „Real 1:1 Mode“ is selected,
see parameter
DISPENSER PARA > Dispense Mode) and prints and dispenses
the next label.
Change the basic parameter setting as follows to use the light barrier for
triggering:
Set
DISPENSER PARA > Start source to „Light barrier“.
Parameters settings for „64-xx dispenser A“
„64-xx dispenser A“ is equipped with a longer dispensing edge which lea-
ves enough space for closing the hood if an applicator is mounted. This
long dispensing edge has no light barrier.
Applicator The „64-xx dispenser A“ is designed to be used with the LTSI applicator.
Advice on printer operation with the LTSI applicator, see Service manual
LTSI.
Advice on setting parameters can be found in topic section Info printouts
and parameters.
Information about operation with start signal can be found in topic section
Advanced Applications