11/14 Rev. 03 USER MANUAL Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x
8
Standalone Operation
Requirements
Printer Suitable printers: all devices listed in the headline of this document, except for AP 4.4
(which has no card slot)
Firmware
CPU board
Options board
Is required for the printer types listed below to be able to connect a keyboard. The or-
der number for the options board can be found in topic section Accessories .
64-xx Gen. 2
•DPM Gen. 2
PEM Gen. 2
ALX 92x Gen. 2
Memory card For order number, see the Plugin Card Manual, topic Available Cards .
Card reader PC or laptop with card reader
Printer Feature Firmware version
64-xx, DPM, PEM, ALX 92x Gen. 2
a
a) Characteristic feature: No USB interfaces, but Centronics as standard.
3.0
64-xx, DPM, PEM, ALX 92x Gen. 3
b
b) Characteristic feature: USB interfaces, Centronics optional.
5.02
ALX 73x -- 6.36
AP 5.4, AP 7.t -- 1.10
AP 5.4 Gen II, AP 5.6 MLK 3.34
[Tab. 6] Minimum firmware requirement for standalone operation.
Printer Feature CPU board number
64-xx, DPM, PEM, ALX 92x Gen. 2 A2292/A2293
64-xx, DPM, PEM, ALX 92x Gen. 3 A6621
PM 3000 -- A6621
AP 5.4, AP 7.t -- A3927
AP 5.4 Gen II, AP 5.6 MLK A100150
[Tab. 7] Minimum CPU board requirement for standalone operation.