11/14 Rev. 03 USER MANUAL Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x
16
Data input by interface
Available with firmware x.33 or a later version.
Apart from putting in data by operation panel or by external keyboard, the data can be
sent via interface.
Application example: Reading in data from a RS232 barcode scanner via serial inter-
face.
Selecting the interface INTERF.PARAM. > OPTIONS > StandAlone Input
Listed are only interfaces, which are available in the printer and are not already oc-
cupied by another function.
Application notes The following characters or character sequences are replaced by respectively one
„Enter“ action, if received.
<CR>
1
<CR><LF>
•<LF>
2
<LF><CR>
Data received at the interface are processed only then, if the printer is switched to
standalone operation.
Example Example of a standalone printjob on the memory card:
#!A1#DC
#IMSR100.08/100.08
#HV50
#PR8/8/
#RX0
#ERN/1//0
#R0/0
#VTS/Var1//10///Test Var1#G
#VTS/Var2//10///Test Var2#G
#T34.16 #J90.75 #FD/0/L #SS100/BVUN/42X42/0 #VW/L/Var1#G
#T34.08 #J79.58 #FD/0/L #SS100/BVUN/42X42/0 #VW/L/Var2#G
#Q1#G
#!P1
The following data is received via the data interface:
Content1<cr><lf>
Content2<cr><lf>
3<cr><lf>
The first two lines assign the content „Content1“ to the variable „Var1“ and the content
„Content2“ to the variable „Var2“. The third line assigns the print quantity „3“.
1) <cr> = 0x0D
2) <lf> = 0x0A

Table of Contents