11/14 Rev. 03 USER MANUAL Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x
20
Transmission with LPD Server
Printing data can be transmitted to the printer using the LPR/LPD (Line Printer Dae-
mon) protocol (“BSD Spooler”).
This protocol is supported by
all Unix derivatives
Windows NT, Windows 2000 und Windows XP
The print queue of the host must be named „lp“!
Example 1. Set parameter INTERF.PARAM. > EASYPLUGINTERPR > Interface to „LPD server“.
2. Send the printjob file (here: „test.txt“) as illustrated using the „lpr“ command [8].
[8] Sending a printjob with the „lpr“ command.
Enter „lpr ?“ to get a list of the admissible command options.
For the use of LPD server under Windows NT or Windows 2000, please refer
to the following link:
http://support.microsoft.com/default.aspx?scid=kb;EN-US;179156
For the use of LPD server under Windows 95 and Windows 98, a software
package from external providers is required (e.g. Windows LPR Spooler, see the
following link).
http://home.arcor.de/Heil-Consulting/
Troubleshooting
The following should be checked if a problem occurs:
Ethernet connection: The yellow LED belonging to the printer network socket must
be illuminated. If this is not the case, possible sources of error are:
that the network is not connected to the outlet.
ISDN outlet: Erroneous, the network cable was connected to an ISDN instead
of a network outlet. Both outlet types do not differ mechanically.
an incorrect cable (ISDN cable?) is used to connect the printer to the network
outlet.
a defective hub/switch.
a defective printer board.
IP parameter: The defined parameters or parameters set via DHCP are displayed
in the “Printer Status” printout. A “ping” to the set IP address must return an echo.
This also works if a different interface is set in the Easy Plug Interpreter parameter.
Possible source of error: Incorrect configuration of a network participant.
On the printer, either “TCP/IP socket” or “LPD server” must be set in the Easy Plug
Interpreter parameter.