Model E1010 Indicator User Instructions 10
2 Introduction
The Model E1010 is an easy to use, uncomplicated indicator for general weighing
applications. It is ideal for bench scales, floor scales and tank weighing applications.
The display includes a multi-segment fan graph for fast visual awareness for
checkweighing. The indicator can perform counting functions, peak weight functions,
act as a remote display and operate on battery power (optional). You can switch
between enabled applications with one key press. The indicator also has 10 PLU
(Product Look Up) memory channels for storing data.
Two communication ports allow connection to a printer, remote display or computer.
The indicator also has three setpoint controls and can accommodate a footswitch for
zero, print or tare function.
All this in an NEMA 6/4X rated enclosure.
2.1 Setup
Your indicator will be installed by a qualified Avery Weigh-Tronix distributor. They will
make the required connections to your scale and peripheral devices.
1. With the unit plugged in, see note below, press and hold the ON/OFF key until
the display lights up, then release the key.
2. The indicator powers up in normal operation mode.
It is important that the battery be kept fully charged, either by the preferred method of
float charging (i.e. keeping the unit permanently plugged into AC power supply) or by
charging for 24 hours every 40-50 days. If a longer period of storage is required and
float charging is not practical, the battery should be disconnected.
If the indicator is sealed for Weights and Measures purposes, disconnecting the battery
may not be possible. In this case the only option is to ensure that the indicator is
connected to the AC supply to keep the battery topped off.
The battery should never be stored in a discharged state as permanent damage will
occur.
The Model E1010 can be battery powered. Charge the battery overnight before using
the indicator on battery power only. The unit can be run on the AC transformer (AC
mains power) if the battery is drained or absent. See Battery Information on page 14
for more information.