Model E1010 Indicator User Instructions 33
4. After OP3 has been set, or skipped, the indicator will automatically return to
normal weighing mode.
8.3 Accumulator Weighing
The accumulator is memory that collects individual weighments (gross and net) and
stores the totals. These totals can be recalled at any time and the number of
weighments included in the totals can be displayed. With the proper password all
information can be deleted. See the PLU (Product Look Up) on page 21.
The accumulator maximum is 999,999. It does not rollover to start over at 0.
To use the accumulator, power up the unit and follow these steps:
1. Empty the scale and press the ZERO key to zero the display…
0 is displayed and gross and center of zero annunciators are lit.
2. Place item on the scale…
Weight is displayed.
3. You can press the PRINT or F1 key to add weight to the accumulator. If you
press PRINT, the weight is accumulated and the information printed. If you
press F1, the weight is accumulated. Scale weight must return to a weight
within the configured gross zero band before another weighment can be
accumulated.
4. Repeat 2 and 3 for each weighment you want to accumulate.
5. To review the accumulator total and the number of weighments, remove all
weight from the scale (the scale must read 0 weight) and press the SELECT
key repeatedly…
1st press = Net weight displayed
2nd press = Tare weight displayed
3rd press = Gross total of all weighments is displayed
4th press = Net total of all weighments is displayed
5th press = Number of weighments is displayed
6th press = Active PLU number is displayed.
7th press = Display returns to gross weigh mode
You need the supervisor’s password to clear the accumulator.
Press the MODE key to scroll through the enabled applications.
You can use tare/net weighing with the accumulator application. The accumulator
stores both gross and net totals for later recall.

Other manuals for Avery Weigh-Tronix E1010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix E1010 and is the answer not in the manual?

Avery Weigh-Tronix E1010 Specifications

General IconGeneral
BrandAvery Weigh-Tronix
ModelE1010
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals