EasyManuals Logo

Avery Weigh-Tronix E1010 Manual

Avery Weigh-Tronix E1010
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Model E1010 Indicator User Instructions 15
5 PLU (Product Look Up) Memory Channels
This indicator has 10 channels of memory called PLU or Product Look Up. Each
channel can contain the following information:
l Channel #
l ID#
l Ta r e
l Gross Accum.
l Net Accum.
l To tal
l TARGET OP1
l TARGET OP2
l TARGET OP3
l Lower Limit
l Upper Limit
l Count Accum.
l Piece Weight
l Peak Weight
1. To activate or recall a PLU, key in the desired channel number (0-9) and press
the F1 key…
The PLU channel is active. Any of the items listed above that have
values are activated. Any values that are listed above that change while
this PLU is active are stored, ie; accumulator, count, etc.
2. PLU channels can be cleared by using a password protected menu. These
instructions are found in the Supervisor Menu on page 18. You can also print a
report of all the PLU channels in the same password protected menu.
If there are preset tares in the PLUs, you cannot enter a keyboard or pushbutton tare.
Preset tares are enabled and entered under the Supervisor Menu on page 17.
If preset tares are not enabled, any tare you enter by keyboard or pushbutton method
will be active for all PLUs.

Other manuals for Avery Weigh-Tronix E1010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix E1010 and is the answer not in the manual?

Avery Weigh-Tronix E1010 Specifications

General IconGeneral
BrandAvery Weigh-Tronix
ModelE1010
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals