Model E1010 Indicator Service Manual
Autoprint will print out the configured print format once, after the weight has
stabilized over the value entered in the steps below. It will not print again
until the scale weight returns to zero and then stabilizes over the autoprint
value.
1. Press the UNITS key. . .
A PRNT is displayed. Use this item to set the autoprint value.
2. Press the PRINT key. . .
Current setting is displayed.
3. Key in your weight choice and press the ENTER key to accept. . .
A PRINT is displayed.
1. Press the UNITS key. . .
LEAD-0 is displayed. Use this item to turn a leading zero on or off
for all system variables.
2. Press the PRINT key. . .
ON or OFF is displayed.
3. Toggle between the choices by using the UNITS key or TARE key and
press the ENTER key to accept the displayed choice. .
LEAD-0 is displayed.
Use the String item to create customized print formats. The default print
format is always = 0. Use this menu to create formats #1-9 and 11-15. See
note at left. Formats #1-9 can be printed by keying in the format number and
pressing the PRINT key.
1. Press the PRINT key. . .
1 is displayed. This is the print format number.
2. Scroll through the list of 1-10 using the UNITS key and press PRINT to
select the displayed choice. . .
A string is displayed. Refer to the section Extra Info: Print Format
Editing to understand how to edit strings.
3. Modify as many formats as you wish and when you are finished press
the ENTER key. . .
STRING is displayed.
4. Press the SELECT key. . .
SERIAL is displayed.
This completes the SERIAL submenu. Press the UNITS key to go to the
TEST submenu or press ZERO to return to normal weighing mode.
LEAD-0
(Leading zero )
STRING
(Custom print formats)
A PRINT
(Autoprint minimum
trigger weight)
Service Menu—SERIAL submenu (continued)
Print Format 0 is the default
print format reserved for each
application mode.
Formats 1-9 are available for
any application mode.
Format 10 = Format 0 for
General weighing mode.
Format 11 = Format 0 for the
ACC mode
Format 12 = Format 0 for the
Batch mode
Format 13 = Format 0 for the
Target mode
Format 14 = Format 0 for the
Count mode
Format 15 = Format 0 for the
Top mode

Other manuals for Avery Weigh-Tronix E1010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix E1010 and is the answer not in the manual?

Avery Weigh-Tronix E1010 Specifications

General IconGeneral
BrandAvery Weigh-Tronix
ModelE1010
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals