4
Model E1010 Indicator Service Manual
Specifications
Power requirements
• 100-240 Volts AC @ 600 mA
• 50/60 Hz
• Optional Internal battery: 23 hours of continuous
operation with one weight sensor; 15 hours of
continuous operation with four weight sensors
• Standby mode extends battery life
Excitation
• 5 volts
• Supports up to four 350-ohm weight sensors
Analog signal input range
• 12 mV/V
Analog signal sensitivity
• 0.5 μV/division minimum
Calibration
• 2 to 5 points stored
Operational keys
• Tare, Select, Zero, Print, Units, F1, Clear, Mode,
Escape, Enter, On/Off, 0-9 numeric and decimal
point
Operational annunciators
• Center of Zero, Motion, Gross, Tare, Net, Battery
status
• Under/Target/Over
• Units of measure (LB, KG, Custom)
• Peak, Print, OP1, OP2, OP3, Count
Display
• Seven-digit, seven-segment, 0. 8-inch high
• Lighted STN Transmissive
• Display rate Selectable (1, 2, 5, 10)
Analog to digital conversion rate
• 60 times per second
Unit of measure:
• Three, independently programmable
• Pounds, Kilograms, Custom
Capacity selections
• 999,999 with decimal located from zero to five
places
Incremental selections
• Multiples and sub-multiples of 1, 2, 5
Programmable selections
• Zero range, motion detection, automatic zero
tracking, five-point linearization
Time and date / RAM
• Battery backed up real time clock and RAM
Internal resolution
• 64,424,509 counts per mV/V per sec
Standard inputs
• Three logic level inputs for: Zero, Print, Tare,
Units, F1
Standard outputs
• Three cutoff outputs, open collector design
• Two serial ports with RS-232. One of the ports can
also be 20mA current loop, or RS-422 or RS-485
Serial outputs
Two serial ports:
• RS-232 / RS-422 / RS-485 / 20mA current loop
• RS-232
Serial Command Inputs
• Programmable serial response to ASCII character
input, SMA protocol, broadcast, enquire, RD-4100,
E-Series remote display
Self diagnostics
Display, keys, inputs, outputs, serial port,
Circuitry protection
• RFI, EMI, and ESD protection
Options
• Trips Interface Unit (TIU3)
Operating applications
• General weighing, simple counting, checkweighing,
accumulation, peak measurement, batching, and
remote display
Operating temperature
• 14 to 104° F (-10 to 40° C) approved
• -4 to 140° F (-20 to 60° C) non-legal
• 10 to 90% noncondensing humidity
Enclosure
• Stainless steel NEMA 6/4X
Dimensions:
• 9.25” W x 9.25” H x4.5 “ D
(23.5cm W x 23.5cm H x 11.4cm D)
(without mounting bracket)
• 9.75" W x 11” H x 7" D
(24.8cm W x 28cm H x 17.8cm D)
(with mounting bracket)
Weight: 11 lb, 5 kg
Agencies:
• NTEP CC# 04-029
Class III/IIIL:10,000 divisions
• OIML Cert. No. R76/1992-GB1-04.09
Class III: 10,000 divisions
• Canadian Weights and Measures pending
• UL/CUL
• CE marked