7
Model E1010 Indicator Service Manual
Battery Information
This unit contains a sealed rechargeable 6 volt, 3.0Ah, lead-acid battery. Life
expectancy of this battery is 3-5 years in standby use or:
180 charging cycles (approx.) if discharged 100%
400 charging cycles (approx.) if discharged 50%
1200 charging cycles (approx.) if discharged 30%
Battery life is 23 hours with one 350 ohm weight sensor and 15 hours with
four 350 ohm weight sensors. Recharge time from complete discharge is 14
hours while powered up and in service (single loadcell). The AC adapter/
charger will charge the battery as it powers the indicator.
Risk of explosion if battery is
replaced by an incorrect type.
Dispose of used batteries
according to the
manufacturer’s instructions.
Use the numeric keypad to enter values.
For example:
• ID entry
• Output target entry
• Preset tare entry
• Password entry
To turn the unit on, press and hold the ON/OFF key until the
backlight turns on. To turn the unit off, press and hold the ON/
OFF key until the unit turns off.