Model E1010 Indicator Service Manual
OUTPUT
(Output test)
20. Press the UNITS key. . .
OUTPUT is displayed. This is the output test item.
21. Press the PRINT key to access the test.
OUT 1 is displayed. This stands for output 1.
22. Press the PRINT key. . .
The display toggles between ON and OFF. This will toggle the
output off and on. Monitor the output to see that it is turning off
and on. Use a Trips Interface Unit (TIU3) or other output device.
23. Stop the test by pressing the SELECT key. . .
OUT 1 is displayed.
24. Press the UNITS key. . .
OUT 2 is displayed.
25. Repeat steps 22 and 23 for outputs 2 and 3. . .
26. Press the SELECT key. . .
OUTPUT is displayed.
26. Press the SELECT key. . .
TEST is displayed.
This completes the TEST section of the menu. Press the ZERO key to
return to normal operating mode or press the UNITS key to move to the next
menu item, AUDIT.