EasyManua.ls Logo

Azbil Micro Flow MQV9005 - Page 81

Azbil Micro Flow MQV9005
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-13
Chapter 7. SPECIFICATIONS
z
MQV0050(J, K)/0200/0500
0 40 80 120 160
200
0
100
200
400
300
500
600
(1)
(2)
(3)
(4)
0 20 40 60 80 100 120
0
40
80
120
160
200
240
MQV0200 MQV0500
0 2 4 6 8 10
0
10
20
40
30
50
60
(1)
(2)
(3)
(4)
MQV0050(J, K)
(1)
(2)
(3)
(4)
Dierential pressure [kPa]
Flow rate [L/min(standard)]
Dierential pressure [kPa]
Flow rate [L/min(standard)]
Dierential pressure [kPa]
Flow rate [L/min(standard)]
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
Outlet pressure condition
(1) 150 kPa(gauge)
(2) 50 kPa(gauge)
(3) 0 kPa(gauge)
(4) –50 kPa(gauge)
Handling Precautions
•
If the outlet pressure is different from the values graphed on the previous
page, calculate the flow rate using the appropriate equation below.
(1) When P2 / P1 > 0.53,
Q=C1 (P1-P2) P2
(2) When P2 / P1 0.53,
Q=C2 • P1
P1: Inlet absolute pressure [kPa (abs)]
P2: Outlet absolute pressure [kPa (abs)]
(Absolute pressure = gauge pressure + 101.3 kPa)
Q: Flow rate [L/min (standard)] , ([mL/min (standard)] for MQV9005/9020/9200)
C1 and C2: Constant values by model
• MQV9005: C1= 0.7097, C2=0.4653
• MQV9020: C1= 0.7097, C2=0.4653
• MQV9200: C1= 3.123, C2=1.559
• MQV9500: C1= 0.03123, C2=0.01559
• MQV0002: C1= 0.03123, C2=0.01559
• MQV0005: C1= 0.3123, C2=0.1559
• MQV0020: C1= 0.3123, C2=0.1559
• MQV0050(B, C): C1= 0.5529, C2=0.2760
• MQV0050(J, K): C1= 2.212, C2=1.104
• MQV0200: C1= 2.212, C2=1.104
• MQV0500: C1= 4.115, C2=2.054
≤
•
When used with the gases other than air, convert the flow rate using the
following equation:
Flow rate = Flow rate in air ÷ specic gravity of gas to be controlled
Example: When using the MQV0002 with CO
2
, inlet pressure = 10 kPa (gauge),
and outlet pressure = 0 kPa (gauge),
1.0 L/min (standard)
÷ 1.53 = 0.81 L/min (standard)
Specific gravity of standard compatible gas (air is taken as 1.0)
Gas type Specific gravity
Oxygen 1.11
Argon 1.38
Carbon dioxide (CO
2
) 1.53
Natural gas 13A (LNG) 0.64
Methane 0.56
Propane 1.56
Butane 2.08