154 ImagePRO-II • User’s Guide
B. Remote Control Protocol
ImagePRO-II Remote Commands
póëíÉã=~åÇ=bíÜÉêåÉí=oÉãçíÉ=`çãã~åÇë
bafafk
Description: EDID Input settings
Required parameters: --con (connector)
Parameters:
--con (connector): 0-3
0 = DVI, 1= HD15, 2 = HDMI, 3 = DP
--vfs (Set/Query EDID video format. See VFS for parameter details.)
Example:
EDIDIN --con 0 --vfs --con 0 --new "1920x1080i
@60"
(Set DVI input EDID to "1920x1080i @60")
bkbq
Description: Ethernet Settings
Command Format:
ENET -i (ip address) -n (mask) -g (gateway) -d (dhcp
mode) --reset (restart enet)
Parameters:
-i (staticip address): xx.xx.xx.xx
-n (mask): xx.xx.xx.xx
-g (gateway): xx.xx.xx.xx
-d (dhcp mode): 0 = no, 1 = yes
--reset (restart enet)
Query Format:
ENET --?
Query Response: Ethernet settings in the following format:
ENET current (ip address) -i (ip address) -n (mask)
-g (gateway) -d (dhcp mode)

Table of Contents