EasyManua.ls Logo

Barco ImagePRO-II - Page 168

Barco ImagePRO-II
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
154 ImagePRO-II • User’s Guide
B. Remote Control Protocol
ImagePRO-II Remote Commands
póëíÉã=~åÇ=bíÜÉêåÉí=oÉãçíÉ=`çãã~åÇë
bafafk
• Description: EDID Input settings
• Required parameters: --con (connector)
• Parameters:
--con (connector): 0-3
0 = DVI, 1= HD15, 2 = HDMI, 3 = DP
--vfs (Set/Query EDID video format. See VFS for parameter details.)
Example:
EDIDIN --con 0 --vfs --con 0 --new "1920x1080i
@60"
(Set DVI input EDID to "1920x1080i @60")
bkbq
• Description: Ethernet Settings
• Command Format:
ENET -i (ip address) -n (mask) -g (gateway) -d (dhcp
mode) --reset (restart enet)
• Parameters:
-i (staticip address): xx.xx.xx.xx
-n (mask): xx.xx.xx.xx
-g (gateway): xx.xx.xx.xx
-d (dhcp mode): 0 = no, 1 = yes
--reset (restart enet)
• Query Format:
ENET --?
• Query Response: Ethernet settings in the following format:
ENET current (ip address) -i (ip address) -n (mask)
-g (gateway) -d (dhcp mode)

Table of Contents