4. Lamp & Lamp House
10
9
2.5Nm
Image 4-27
2. Install the anode w ire lug ( reference 6 im age 4- 28) upon the anode socket a s illustrated. Use an 8mm A llen torque key set to
9Nm (6.64lbf*ft) to s ecure the bolt (reference 8 image 4-28). Place a at washer (reference 7 image 4-28) between the bolt and
thewirelug.
Warning: Make s ure that there is no tension on the anode wire of the xenon lamp.
9Nm
6
7
8
Image 4-28
Tip: Write do wn the serial number of the xenon lamp. You will need this while updating the lam p parameters after installation
of the xenon lam p. T he s erial num b
er of the xenon lamp is engr aved in the neck of the xenon lamp .
3. Check the cathode connection inside the lamp house. Use an 22 m m open-end wrench to hold the rst nut while fastening the
second nut on the rod with a torque of 25Nm (18.4 lbf*ft) using a torque wrench with 22 m m hex agon soc ket. Ensure that there
is a at washe r at both sides of the w ire lug. It’s safer to do this check be fore t he xenon lamp is installed to avoid accidental
bumping agains t the xenon lamp.
Tip: The cathode so cket can easily pulled out from the Lamp House as a whole to perform this check.
Caution: These cathode connections must be checked with every lam p change!
25 Nm
Image 4-29
54 R5905963 PROMETHEUS SERIES 09/03/2015