PARAMETER RANGE
OF
VALUES
DEFAULT
VALUE
FUNCTION
Angle4
Ø
°
-89
°
Ø
°
Rotates a pattern counterclock
-
wise, in 1
°
increments.
Origin5 ON/OFF ON When On, automatically returns
the pantograph to the pattern ori
-
gin, when sewing has been com
-
pleted.
Socks6 Ø-3 Ø Used for the sock frame attach
-
ment, automatically programs two
repetitions of a pattern, letting you
set up spacing between each pat
-
tern for the frame that will be
used.Ø=Off
1 = On - Normal setup
2 = On - second repetition mir
-
rored
3 = On - second repetition rotated
180
°
When Socks is on, Origin (# 5) is
automatically turned off, so the
machine can alternate between
two origin points. See the
Me-
chanical Guide
for instructions.
Appliqué7 ON/OFF OFF Moves the pantograph forward for
easy placement of appliqué fabric.
The default movement is 1-1/2
times the height of the pattern. A
new value can be programmed in
the A. Offset parameter.
A. Offset8 -999mm to
300mm
Ømm Sets the amount the pantograph
will move when Appliqué is on. If
set at Ø, the pantograph moves
1-1/2 times the height of the pat
-
tern.
2-16 Memory Operations BENS Operation Guide - 12/99