Error detection and troubleshooting
Compact manual b maXX
®
BM4400, BM4600, BM4700
Document no.: 5.06014.02
87
of 94
8
8.2.3 Parameter description – warnings (warning bit list)
Warning power supply P0261
4174 Configuration cyclic services: Parame-
ters are not cyclic writable
adjustable Select another parameter
4175 Configuration cyclic services: Invalid
parameter number
adjustable Select another parameter
4176 Wrong option module error code adjustable Contact Baumüller
4177 to 8191 reserved
8192 Error CANopen timeout on CAN bus adjustable Error node guarding
Further information is to be found in program-
ming manual CANopen Slave for b maXX
®
controller
Sub-error no. Meaning Reaction Troubleshooting
Warning no. Meaning Troubleshooting
0 reserved warning
1 Undervoltage 24V Assure the compliance with the specification
2 Mains undervoltage Assure the compliance with the mains specification
3 Mains overvoltage Assure the compliance with the mains specification
4 Mains failure Restore the mains supply
5 Phase failure Check if all phases are correctly connected and volt-
age-carrying
6 to 15 reserved warning