DS-RPC OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
__________________________________________________________________________________________
42
If enabled, the following header and menu
appears:
Data Switch Series - F.0.10
Bay Technical Associates
Unit ID: DS71
Port Select Code: $BT
Attention Character: ;
Device A (2,1)...............1
Device B (2,2)...............2
Device C (2,3)...............3
Device D (2,4)...............4
Configure.................................C
I/O Modules Reset...................RM
Unit Reset.................................RU
Exit............................................X
Logout.......................................T
Enter Request:
Select #3, “Menu,” from the selection menu,
followed by <cr>. The DS71 or DS71-MD2
module displays the current menu status and
asks if you want to enable:
Menu is............................ Disabled
Enable? (Y/N, CR for no change):
Type “Y” for yes followed by <cr> if you
want to enable Menu. Type “N“ for no
followed by <cr> if you want to disable
Menu. Type <cr> for no change.
NOTE: If Auto Connect Port is enabled, Header and Menu are
automatically disabled.
Auto Connect Port If Auto Connect Port has been enabled, the
initiation of power to the DS71 or DS71-MD2
module will connect the user to the
designated I/O port. This also happens when a
modem connection is established.

Table of Contents