20
Functional desctription:
If there is an error at one of the lubrication cycles, lubricant comes out of the pump element with pressure limiting valve
( ig. 11).F
If a pressure limiting valve (version ball valve) is integrated, lubricant is supplied into the pump‘s store room ( ig. 12).F
Fig. 11: Fig. 12:
Use of integrated pressure limiting valves in the pump GIGAPLUS
The use of integrated pressure limiting valves are possible but limited depending on the application of the GIGAPLUS.
If the pump, with or without control unit, is installed in a , up to threeprogressive central lubrication system
independent lubrication cycles can be operated with an in eachintegrated pressure limiting valve (version ball valve)
case.
If a is operated with the pump (only integrated control unit GIGA multitronic),sectional system pump elements with
installed pressure limiting valves have to be used as the installation position is already occupied.
If a is operated with the pump, with or without control unit, ansingle line system integrated pressure limiting valve
(version piston valve) shall be installed.
If the pump, with or without control unit, is installed in a ,dual line lubrication system pump elements with installed
Pressure limiting valves have to be used as the installation position is already occupied by the magnetic valves.
Grease outlet

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BEKA BEKA-MAX GIGA and is the answer not in the manual?

BEKA BEKA-MAX GIGA Specifications

General IconGeneral
BrandBEKA
ModelBEKA-MAX GIGA
CategoryWater Pump
LanguageEnglish

Related product manuals