7.6 Outlet fittings for the central lubrication pump GIGAPLUS
The Order key is used to order the pump outlet with a swivelling screw joint pipe Ø 6, 8 or 10 or without an outlet fitting with
connection thread G1/4".
Fig. 15:
7.5 Level monitoring device min.
The central lubrication pumps GIGA and GIGA PLUS can be equipped with an integrated level monitoring device. For
this, a capacitive proximity switch is installed in the pump body.
Function description:
The proximity switch transmits a signal until there is sufficient lubricant in the reservoir. If the fill level falls below a certain
level, the proximity switch stops the signal. The central lubrication pump is switched off to prevent air entering the system.
Fig. 16: The signal from the proximity switch can also be evaluated
by an existing signal transmitter such as an SPS or on-board
computer. For this, on the side of the motor cover is a 4-pin
plug-in connection with a red identification nut. Cables of
various lengths can be plugged into this connection (see 15.
List of spare parts and 16. Drawing of spare parts).
Level switch
(optional)
Outlet fitting
Pump element
22