Installation GRS105/GRS106
Release
01
11/2021
63
13.5 Climatic conditions during operation
13.6 Climatic conditions during storage
Connection type 2-pin terminal block
Tightening torque 0.34 Nm (3 lb-in)
Minimum conductor diameter 0.08 mm² (AWG28)
Maximum conductor diameter 2.5 mm² (AWG12)
Climatic conditions during operation
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 5 cm (2 in) from the device.
-10 °C ... +60 °C (+14 °F ... +140 °F)
Maximum internal air temperature
b
b. Temperature measured by the temperature sensor within the device.
+65 °C (+149 °F)
Humidity 5 % ... 95 % (non-condensing)
Air pressure min. 600 hPa (+4000 m/+13123 ft ASL),
max. 1060 hPa (-400 m/-1312 ft ASL)
Table 20: Climatic conditions during operation
Climatic conditions during storage
Ambient air temperature -10 °C ... +60 °C (+14 °F ... +140 °F)
Humidity 5 % ... 90 % (non-condensing)
Air pressure min. 600 hPa (+4000 m/+13123 ft ASL),
max. 1060 hPa (-400 m/-1312 ft ASL)
Table 21: Climatic conditions during storage
Signal contact
Table 19: Signal contact