EasyManua.ls Logo

Belden HIRSCHMANN GRS106 - EMC and Immunity Standards; EMC Interference Emission Standards; EMC Interference Immunity Standards

Belden HIRSCHMANN GRS106
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation GRS105/GRS106
Release
01
11/2021
65
14 EMC and immunity
EMC interference emission Standard applications Railway applications (trackside)
EN 55032 Class A Fulfilled Fulfilled
FCC 47 CFR Part 15 Class A Fulfilled Fulfilled
EN 61000-6-4 Fulfilled Fulfilled
Table 22: EMC and immunity: EMC interference emission
EMC interference immunity Standard applications
a
a. According to EN 61000-6-2.
Railway applications (trackside)
b
b. According to EN 50121-4.
Electrostatic discharge
EN 61000-4-2 Contact discharge ±4 kV ±6 kV
EN 61000-4-2 Air discharge ±8 kV ±8 kV
Electromagnetic field
EN 61000-4-3 80 MHz ... 6000 MHz max. 10 V/m max. 20 V/m
Fast transients (burst)
EN 61000-4-4 Supply voltage connection ±2 kV ±2 kV
EN 61000-4-4 Data line ±4 kV ±2 kV
Voltage surges - AC supply connection
EN 61000-4-5 line/ground ±2 kV ±2 kV
EN 61000-4-5 line/line ±1 kV ±1 kV
Voltage surges - data line
EN 61000-4-5 line/ground ±1 kV ±2 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V 10 V
Table 23: EMC and immunity: EMC interference immunity