30
Installation OCTOPUS 8TX-EEC
Release
07
01/2021
2 Installation
The devices have been developed for practical application in a harsh
industrial environment.
On delivery, the device is ready for operation.
Perform the following steps to install and configure the device:
Checking the package contents
Installing and grounding the device
Connecting the power supply and the signal contact lines
Operating the device
Connecting data cables
Configuration (optional)
2.1 Checking the package contents
Check whether the package includes all items named in the section
“Scope of delivery” on page 54.
Check the individual parts for transport damage.
2.2 Installing and grounding the device
2.2.1 Mounting on a flat surface
Requirements:
Select the installation site so that the climatic threshold values listed in the
technical data are observed.
See “Technical data” on page 47.
To protect the exposed uninstalled contacts of the components from dirt,
connect the individual system components in a dry and clean working
area.
To sustain the IP65/67 suitability for your device, seal all unused
connections and ports with the provided plastic protection screws. See
“Scope of delivery” on page 54. See “Accessories” on page 54 in case of
an additional demand.
To sustain the IP65/67 suitability for your device, exclusively connect
components with degree of protection IP65/67.
Note: The torque for tightening the protection screws on the device is
5.3 lb-in (0.6 Nm).