52
Installation OCTOPUS 8TX-EEC
Release
07
01/2021
7.3 EMC and immunity
7.4 Network range
EMC interference emission
Radiated emission
EN 55032 Class A
FCC 47 CFR Part 15 Class A
EN 61000-6-4 Fulfilled
Conducted emission
EN 55032 Supply connection Class A
FCC 47 CFR Part 15 Supply connection Class A
EN 61000-6-4 Supply connection Fulfilled
EN 55032 Telecommunication connections Class A
EN 61000-6-4 Telecommunication connections Fulfilled
EMC interference immunity
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge ±6 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge ±8 kV
Electromagnetic field
EN 61000-4-3 max. 20 V/m
Fast transients (burst)
EN 61000-4-4 Supply connection ±2 kV
EN 61000-4-4 Data line ±4 kV
Voltage surges - DC supply connection
EN 61000-4-5 line/ground ±2 kV
EN 61000-4-5 line/line ±1 kV
Voltage surges - data line
EN 61000-4-5 line/ground ±2 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V
Immunity
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with
0.14 in (3.5 mm)
amplitude
8.4 Hz ... 150 Hz with 1 g
IEC 60068-2-27, test Ea Shock 15 g at 11 ms
10/100/1000 Mbit/s twisted pair port
Length of a twisted pair segment max. 328 ft (100 m) (for Cat5e cable)
Table 3: Network range: 10/100/1000 Mbit/s twisted pair port