Installation OCTOPUS 8TX-EEC
Release
07
01/2021
3 Making basic settings
This applies to the following device variants only:
OCTOPUS 8TX-EEC-M
Note: 2 or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
The IP parameters must be entered when the device is installed for the first
time. The device provides the following options for configuring IP addresses:
Input via the HiView or Industrial HiVision application. You find further
information about the applications HiView or Industrial HiVision on the
Internet at the Hirschmann product pages:
HiView
http://www.hirschmann.com/en/QR/INET-HiView
Industrial HiVision
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
Configuration via BOOTP
Configuration via DHCP (Option 82)
AutoConfiguration Adapter ACA22-M12-C (EEC)
Configuration via ACA22-C interface
Default settings
IP address: The device looks for the IP address using DHCP
Management password:
user, password: public (read only)
admin, password: private (read/write)
Ethernet ports: link status is not evaluated (signal contact)
RSTP (Rapid Spanning Tree) activated