Installation OCTOPUS 8TX-EEC
Release
07
01/2021
Power supply
OCTOPUS 8TX-EEC-M
Rated voltage DC: 24/36 V DC
Voltage range DC incl.
maximum tolerances:
16.8 V DC ... 45 V DC
Connection type 5-pin, “A”-coded M12 connector
Power loss buffer >10 ms
Back-up fuse for each voltage
input when supplied via 1 input
Nominal rating:
Characteristic:
2 A ... 10 A
slow blow
Back-up fuse for each voltage
input when supply is via 2
inputs
Nominal rating:
Characteristic:
2 A ... 10 A
slow blow
Peak inrush current 1.2 A
Current integral I²t <0,1 A
2
s
Climatic conditions
during operation
Ambient air temperature
a
up to 6562 ft ASL
(2000 m ASL)
-40 °F ... +158 °F
(-40 °C ... +70 °C)
6562 ft ASL ...
13123 ft ASL
(2000 m ASL ...
4000 m ASL)
-40 °F ... +149 °F
(-40 °C ... +65 °C)
Humidity 5 % ... 100 %
(also in condensing atmospheres)
Air pressure Without derating min. 795 hPa
(+6562 ft;
+2000 m)
max. 1060 hPa
(-1312 ft; -400 m)
With derating min. 600 hPa
(+13123 ft;
+4000 m)
max. 1060 hPa
(-1312 ft; -400 m)
Climatic conditions
during storage
Ambient air temperature
a
-40 °F ... +185 °F
(-40 °C ... +85 °C)
up to 3 months
-40 °F ... +158 °F
(-40 °C ... +70 °C)
up to 1 year
-40 °F ... +122 °F
(-40 °C ... +50 °C)
up to 2 years
+32 °F ... +86 °F
(0 °C ... +30 °C)
up to 10 years
Humidity 5 % ... 100 %
(also in condensing atmospheres)
Air pressure min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (-1312 ft; -400 m)
Protection classes Degree of protection IP65/67
Pollution degree 4