EasyManua.ls Logo

Belden Hirschmann OCTOPUS 8TX PoE-EEC - Page 48

Belden Hirschmann OCTOPUS 8TX PoE-EEC
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
Installation OCTOPUS 8TX-EEC
Release
07
01/2021
Power supply
OCTOPUS 8TX-EEC-M
Rated voltage DC: 24/36 V DC
Voltage range DC incl.
maximum tolerances:
16.8 V DC ... 45 V DC
Connection type 5-pin, “A”-coded M12 connector
Power loss buffer >10 ms
Back-up fuse for each voltage
input when supplied via 1 input
Nominal rating:
Characteristic:
2 A ... 10 A
slow blow
Back-up fuse for each voltage
input when supply is via 2
inputs
Nominal rating:
Characteristic:
2 A ... 10 A
slow blow
Peak inrush current 1.2 A
Current integral I²t <0,1 A
2
s
Climatic conditions
during operation
Ambient air temperature
a
up to 6562 ft ASL
(2000 m ASL)
-40 °F ... +158 °F
(-40 °C ... +70 °C)
6562 ft ASL ...
13123 ft ASL
(2000 m ASL ...
4000 m ASL)
-40 °F ... +149 °F
(-40 °C ... +65 °C)
Humidity 5 % ... 100 %
(also in condensing atmospheres)
Air pressure Without derating min. 795 hPa
(+6562 ft;
+2000 m)
max. 1060 hPa
(-1312 ft; -400 m)
With derating min. 600 hPa
(+13123 ft;
+4000 m)
max. 1060 hPa
(-1312 ft; -400 m)
Climatic conditions
during storage
Ambient air temperature
a
-40 °F ... +185 °F
(-40 °C ... +85 °C)
up to 3 months
-40 °F ... +158 °F
(-40 °C ... +70 °C)
up to 1 year
-40 °F ... +122 °F
(-40 °C ... +50 °C)
up to 2 years
+32 °F ... +86 °F
(0 °C ... +30 °C)
up to 10 years
Humidity 5 % ... 100 %
(also in condensing atmospheres)
Air pressure min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (-1312 ft; -400 m)
Protection classes Degree of protection IP65/67
Pollution degree 4
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device