Technical specifications
63
COM465IP-COM465DP_D00216_02_M_XXEN/03.2017
Climate classes acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ........................................................... 3K5 (except condensation and formation of ice)
Transport (IEC 60721-3-2) ........................................................................................................................................... 2K3
Long-term storage (IEC 60721-3-1) ........................................................................................................................... 1K4
Mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) .................................................................................................................................. 3M4
Transport (IEC 60721-3-2) .......................................................................................................................................... 2M2
Long-term storage (IEC 60721-3-1) .......................................................................................................................... 1M3
Connection
Connection type.................................................................................................................pluggable push-wire terminals
Push-wire terminals
Conductor sizes..................................................................................................................................................AWG 24-12
Stripping length........................................................................................................................................................ 10 mm
rigid/flexible ................................................................................................................................................0.2…2.5 mm²
flexible with ferrule with/without plastic sleeve .....................................................................................0.25…2.5 mm²
Multiple conductor, flexible with TWIN ferrule with plastic sleeve.......................................................... 0.5…1.5 mm²
Push-wire terminal X1
Conductor sizes..................................................................................................................................................AWG 24-16
Stripping length........................................................................................................................................................ 10 mm
rigid/flexible ................................................................................................................................................0.2…1.5 mm²
flexible with ferrule without plastic sleeve...............................................................................................0.25…1.5 mm²
flexible with ferrule with plastic sleeve ..................................................................................................0.25…0.75 mm²
Miscellaneous
Operating mode ............................................................................................................................... Continuous operation
Mounting position .........................................................Front-orientated, air must pass through cooling slots vertically
Degree of protection, internal components (IEC 60529) ........................................................................................... IP30
Degree of protection, terminals (IEC 60529) .............................................................................................................. IP20
Snap-on mounting on a DIN rail ........................................................................................................................ IEC 60715
Screw mounting ...................................................................................................................................................... 2 x M4
Type of enclosure ......................................................................................................................................................... J460
Enclosure material........................................................................................................................................ Polycarbonate
Flammability class ................................................................................................................................................ UL94V-0
Dimensions (W x H x D) ................................................................................................................... 107.5 x 93 x 62.9 mm
Software version ......................................................................................................................................................... D472
Documentation number.......................................................................................................................................... D00216
Weight ................................................................................................................................................................... ≤ 240 g
( )* = Factory setting
8.2 Standards, approvals and certificates
Certification by the PROFIBUS Nutzerorganisation e.V. (PNO) is available.
PROFIBUS conformity: Z02007