Data
72
EDS460-490_D00085_01_M_XXEN/02.2016
LC display ...........................................................................................................backlit graphical display (EDS4…-D)
7-segment display.................................................................................................................2 x 7.62 mm (EDS4…-L)
History memory ..............................................................................................................300 data records (EDS4…-D)
Password ........................................................................................................................................... off/0…999 (off)*
Language................................................................................................................................................... D, GB, F (GB)*
Fault memory alarm relay .......................................................................................................................... on/off (off)*
Inputs/outputs
Test/reset button ..................................................................................................................................internal/external
Cable length for external test/reset button.....................................................................................................0…10 m
Interface
Interface/protocol .......................................................................................................................................RS-485/BMS
Baud rate ..........................................................................................................................................................9.6 kbit/s
Cable length ................................................................................................................................................0…1200 m
Recommended cable (shielded, shield on one side connected to PE) ........................................ J-Y(St)Y min. 2 x 0.8
Terminating resistor ....................................................................... 120 (0.25 W) can be connected via DIP switch
Device address, BMS bus ........................................................................................................................... 1…90 (2)*
EDS - measuring current transformer connection
Single wire 0.75 mm
2
................................................................................................................................... 0…1 m
Single wire, twisted 0.75 mm
2
....................................................................................................................1…10 m
Shielded cable 0.5 mm
2
............................................................................................................................10…40 m
Recommended cable (shielded, shield connected to L conductor, not earthed)....................... J-Y (St)Y min. 2 x 0.8
Switching elements
Number ..................................................................................two relays, each with one changeover contact (EDS46.)
.................................two relays, each with one changeover contact, 12 relays, each with one N/O contact (EDS49.)
Operating principle ...........................................................................N/C operation/ N/O operation (N/O operation)*
Electrical endurance under rated operating conditions, number of cycles.........................................................10.000
Contact data acc. to IEC 60947-5-1
Utilisation category....................................................................................... AC-13 AC-14 DC-12 DC-12 DC-12
Rated operational voltage.............................................................................230 V 230 V 24 V 110 V 220 V
Rated operational current (common alarm relay)............................................5 A 3 A 1 A 0.2 A 0.1 A
Rated operational current (alarm relay)............................................................ 2 A 0.5 A 5 A 0.2 A 0.1 A
Minimum contact rating............................................................................................................. 1 mA at AC/DC 10 V