EasyManuals Logo

Bender ISOMETER isoEV425 User Manual

Bender ISOMETER isoEV425
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
Modbus register assignment of the ISOMETER®
45
isoEV425_D00126_09_M_XXEN/03.2019
Register
Property Description Format
Unit
Value range
999 RO
Number of Mod-
bus
measured
value channels
with active alarm
UINT 16 --- 0…3
3000 RW Reserved --- --- ---
3001 RW Reserved --- --- ---
3002 RW Reserved --- --- ---
3003 RW Reserved --- --- ---
3004 RW Reserved --- --- ---
3005 RW
Pre-alarm value
resistance meas-
urement "R1"
UINT 16 k R2 … 500
3006 RW Reserved --- --- ---
3007 RW
Alarm value
resistance meas-
urement "R2"
UINT 16 k 1 … R1
3008 RW
Activation alarm
value undervolt-
age "U<"
UINT 16 ---
0 = Inactive
1 = Active
3009 RW
Alarm value
undervoltage
"U<"
UINT 16 V 30 … U>
3010 RW
Activation alarm
value overvolt-
age "U>"
UINT 16 ---
0 = Inactive
1 = Active
3011 RW
Alarm value
Overvoltage
"U >"
UINT 16 V U< … 1.15k