Power Temp Light Status & Description
Green - - Burn-in ON
Green Green Green Burn-in OFF
Lamp Error Messages
Power Temp Light Status & Description
- - Red Lamp1 error in normal operation
- -
Red
Flashing
Lamp is not lit up
Thermal Error Messages
Power Temp Light Status & Description
Red Red -
Fan 1 error (the actual fan speed is outside the desired
speed)
Red
Red
Flashing
-
Fan 2 error (the actual fan speed is outside the desired
speed)
Red Green -
Fan 3 error(the actual fan speed is outside the desired
speed)eed)
Red
Green
Flashing
-
Fan 4 error (the actual fan speed is outside the desired
speed)
Red
Flashing
Red
-
Fan 5 error (the actual fan speed is outside the desired
speed)
Red
Flashing
Red
Flashing
-
Fan 6 error (the actual fan speed is outside the desired
speed)
Red
Flashing
Green -
Fan 7 error (the actual fan speed is outside the desired
speed)
Green Red - Temperature 1 error (over limited temperature)
Green
Red
Flashing
- Thermal Sensor 1 open error
Green Green - Thermal Sensor 1 short error
Green
Green
Flashing
- Thermal IC #1 I2C Connection error
Green
Flashing
Red - Temperature 2 error (over limited temperature)
Green
Flashing
Red
Flashing
- Thermal Sensor 2 open error
Green
Flashing
Green - Thermal Sensor 2 short error
Green
Flashing
Green
Flashing
- Thermal IC #2 I2C Connection error
Green Red Red Temperature 3 error (over limited temperature)