EasyManua.ls Logo

BERMAD M10 - Measuring Accuracy; Accuracy Class

BERMAD M10
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M10
Instruction Manual
14
3.4 MEASURING ACCURACY
3.4.1 Reference Conditions:

Measuring liquid: water

Conductivity: >200 µs/cm

Temperature: 20°C

Pressure: 1 bar / 10Mpa

Upstream diameters: ≥ 5 DN

Downstream diameters: ≥ 3 DN
3.4.2 ACCURACY CLASS
ISO 20456: Q1÷Q2: ±0,45mm/s
Q2÷Q4: ±0,5% ±0.35mm/s
ISO 4064/OIML R49: R400 - Class 2