Instruction Manual
8
MID IDENTIFICATION PLATE:

CE conformity mark

Model: Instrument Model

S/N: Meter Serial Number

DN80/3”. PN16: Nominal diameter and MAP

Q3: permanent flow rate

R: ratio

∆p: pressure loss class.

M1 O: Environmental Class

E2: Electromagnetic class

T: Non resettable totalizers

P: Resettable totalizers

12Vdc / Battery: power supply, to be selected during
commissioning

Rep.: Date within battery must be replaced

This symbol means that the product must be
disposed of according to the legal requirements.
The identification plate must never be removed, damaged or changed. It must also be kept clean from
any dirt deposits, as the data contained are the only safe and unambiguous way to recognize the type of
flowmeter and it allows to complete the repair request form attached to this manual.
1.5 APPLICATIONS
M10 is widely used for purposes in which it is important to measure the flow rate of electrically
conductive liquids. Examples of typical applications for the M10 meter are:

Irrigation

Greenhouses

Waterworks

DMA District Metered Areas

Leak detection systems

Remote applications without access to electrical grid

Building and Cooling Systems
Fig. 2 MID
M10
S/N: N7K0059
DN80/3” - PN16
R400
T50
∆p16
M1
E1
IP68
PN: M070080G16PF2AB
T: Noon resettable P: Resettable
12VDC
BATTERY
- Rep. mm/aaaa
M21
0122