M10
Instruction Manual
8
MID IDENTIFICATION PLATE:
CE conformity mark
Model: Instrument Model
S/N: Meter Serial Number
DN80/3”. PN16: Nominal diameter and MAP
Q3: permanent flow rate
R: ratio
∆p: pressure loss class.
M1 O: Environmental Class
E2: Electromagnetic class
T: Non resettable totalizers
P: Resettable totalizers
12Vdc / Battery: power supply, to be selected during
commissioning
Rep.: Date within battery must be replaced
This symbol means that the product must be
disposed of according to the legal requirements.
The identification plate must never be removed, damaged or changed. It must also be kept clean from
any dirt deposits, as the data contained are the only safe and unambiguous way to recognize the type of
flowmeter and it allows to complete the repair request form attached to this manual.
1.5 APPLICATIONS
M10 is widely used for purposes in which it is important to measure the flow rate of electrically
conductive liquids. Examples of typical applications for the M10 meter are:
Irrigation
Greenhouses
Waterworks
DMA District Metered Areas
Leak detection systems
Remote applications without access to electrical grid
Building and Cooling Systems
Fig. 2 MID
M10
S/N: N7K0059
DN80/3” - PN16
R400
T50
∆p16
M1
E1
IP68
PN: M070080G16PF2AB
T: Noon resettable P: Resettable
12VDC
BATTERY
- Rep. mm/aaaa
M21
0122