BestCode Next Series 8 Technical Manual October 2022 Page 165 of 290
Memory device not detected.
Displayed to indicate a fatal error with the internal file system (NOR).
Install USB and Scan External device. Then Erase and Reformat Memory.
Replace the main Circuit Board
The FPGA did not load properly.
Displayed to indicate a fatal error loading the FPGA.
Replace the main Circuit Board
"The message is out of memory."
Displayed to indicate that an element could not be allocated to add to a message being created or
editted.
Message is at maximum length. Adjust message to reduce number of fields then try again.
"Process script failed: %ls"
Displayed to indicate that a script could not be parsed.
Install USB and Scan External device. Then Erase and Reformat Memory.
Translator file format error: %ls
Written to the event log to indicate that the format of a translation file was not valid.
Scan external device to ensure USB is not corrupted. Perform Restore function
(Service>Tools>Restore)
Translation files are not saved correctly. Re-create and save the translation file correctly.
Import script failed: %ls
Displayed to indicate that the specified script could not be read.
Scan external device to ensure USB is not corrupted. Perform Restore function
(Service>Tools>Restore)
Load Firmware Via the J-Link tool
"Print file not found: %ls"
Indicates that the specified file could not be found.
Scan external device to ensure USB is not corrupted. Perform “Erase and Reformat Memory.”