BestCode Next Series 8 Technical Manual October 2022 Page 171 of 290
Phase drops not detected.
Perform Backflush Nozzle then start jet, repeat up to 7 times
Perform modulation calibration (including setting the Charge% to normal range.)
Replace the Drop Generator
Replace the Printhead Umbilical
Replace the Main Circuit Board
Phase signal not detected.
Indicates that no phase signal is detected in the printhead.
Perform modulation calibration (including setting the Charge% to normal range.)
Replace the Main Circuit Board
Replace the Printhead Umbilical
The phase threshold is at maximum.
Press OK and let system return to normal Phase Threshold value.
Clean the printhead and perform modulation calibration
Replace the Printhead Umbilical
System only operates 30 minutes while errors are disabled
Press OK. Enable Phase and Errors, and then Start the Jet.
"Phase quality is too low.
Indicates that phase quality is below minimum and jet will be stopped.
System only operates 30 minutes while errors are disabled
Occurs when enabling Phase from the Service Screen.
Check Ink Viscosity and Modulation Calibration.
Perform Phase Threshold Reset function in the technician screen