"Pump pressure too high to operate %ls."
Indicates pump pressure is higher than the maximum allowed (58 PSI).
Check venturi for clogs. Replace if necessary.
Replace the pressure transducer and cable.
Pump rotation not detected.
Ensure Pump Cable is plugged into J1 Fluid Pump on the Main Board.
Manually clean the Ink Pump
Pump circuit damaged. Replace Main PCB
Pump rotation too low to operate.
Indicates that the pump rotation (RPS) is zero after the "Ready” state was achieved. The pump stalled
or signal was disrupted.
Check Pump Cable for damage.
Manually clean the Ink Pump
Pump circuit damaged. Replace Main PCB
Pump RFID SmartLabel is invalid for the machine type.
Wrong pump type for the machine. Check pump section in this manual.
Manually set pump type in the Technician: Configure Screen.
Indicates that a pump rotation too low error occurred.
Check for clogged venturi
Indicates that a pump rotation too high error occurred.