BL-E30-0515 - 03-01-2018 4-9
Table 4-2 Programmable Parameters - Continued
Parameter Factory Setting Description
70A 90A
SPEED MENU
Max Speed
Mode 1
Mode 2
100%
100%
100%
30%
During forward operation, defines the requested speed at full
throttle when the speed limit pot is in its maximum speed
position.
Note: Allowable range is restricted by the M1/M2 Min Speed
setting.
Min Speed
Mode 1
Mode 2
20%
20%
20%
20%
During forward operation, defines the requested speed com-
mand at full throttle when the speed limit pot is in its minimum
speed position. Min Speed cannot be set higher than the pro-
grammed Max Speed.
Note: Allowable range is restricted by the M1/M2 Max Speed
setting.
Note: For this parameter to apply, a speed limit pot must be
installed in parallel with the throttle and the Speed Limit Pot
parameter must be programmed On (see Throttle menu).
Rev Max Speed
Mode 1
Mode 2
100%
60%
100%
30%
During reverse operation, defines the requested speed at full
throttle when he speed limit pot is in its maximum speed posi-
tion.
Note: Allowable range is restricted by M1/M2 Rev Min Speed
setting.
Rev Min Speed
Mode 1
Mode 2
10%
10%
10%
10%
During reverse operation, defines the requested speed com-
mand at full throttle when the speed limit pot is in its minimum
speed position. Rev Min Speed cannot be set higher than the
programmed Rev Max Speed.
Note: Allowable range is restricted by M1/M2 Rev Max Speed
setting.
Note: For this parameter to apply, a speed limit pot must be
installed in parallel with the throttle and the Speed Limit Pot
parameter must be programmed On (see Throttle menu).