Do you have a question about the Bistos BT-770 and is the answer not in the manual?
Product Name | BT-770 |
---|---|
Category | Fetal Monitor |
Frequency | 1 MHz |
FHR Method | Ultrasound Doppler |
Display | LCD |
Printing | Built-in Thermal Printer |
Power | AC 100-240V, 50/60Hz |
UC Method | External |
FHR Range | 50 to 210 BPM |
Measurement Method | Doppler ultrasound |
Pulse Rate Range | 30-240 bpm |
Power Supply | Rechargeable Battery |
General precautions, warnings, and cautions for safe operation.
Information regarding electrical shock hazards and prevention.
Warnings and precautions related to the device's battery.
Precautions for operating the monitor in different environments.
Defines the intended use, patient population, user profile, and environment.
Explains the fundamental operating principle of the monitor.
Lists the basic and optional configurations of the BT-770 monitor.
Provides visual overviews of the monitor's front, side, and rear views.
Details the monitor's components across front, side, and rear views.
Explains the different areas of the standard display screen.
Details the function of the monitor's smart hotkeys.
Describes the core functionalities and performance of the patient monitor.
Steps and requirements for installing the patient monitor.
Instructions for unpacking and checking the monitor and accessories.
Specifies the necessary space and placement guidelines for the monitor.
Details the power input requirements for the monitor.
Outlines the required environmental conditions for operation, transport, and storage.
Step-by-step guide for powering on the patient monitor.
Instructions for safely powering off the patient monitor.
Covers using the control knob, keys, touch screen, and soft keyboard.
Explains the different operating modes of the monitor.
Guides on setting up measurements for various parameters.
How to freeze and unfreeze waveforms on the monitor.
Covers general monitor settings like defining, language, date/time, and volume.
How to access and use the patient setup menu.
Steps for admitting a new patient into the monitor.
How to edit and input detailed patient information.
Procedure for discharging a patient from the monitor.
How to clear active alarms on the monitor.
Procedure for clearing historical trend data.
Procedure for clearing NIBP trend data.
How to choose between different display formats for the monitor.
Describes various display formats including Normal, Big ECG, Big Font, and 7-Lead ECG.
Classification of alarms into physiological, technical, and prompt messages.
Prioritization of alarms based on severity (high, medium, low).
How the monitor uses visual and audible cues for alarms.
How to manage alarm states like reset, sound off, pause, and off.
How to configure alarm settings like delay time, reminder, and parameter limits.
How to configure physiological alarms to latch or not latch.
How to manually record events during monitoring.
Information on storing and managing alarm records.
Introduction to ECG monitoring and its parameters.
Safety precautions specific to ECG monitoring.
Steps for preparing and performing ECG monitoring.
How ECG waveforms and parameters are displayed.
How to configure ECG settings like HR source, wave gain, and filters.
How to set up ECG-related alarms.
Introduction to respiration monitoring using bioimpedance.
Safety precautions for respiration monitoring.
How to place electrodes for accurate respiration signals.
Explains cardiomotility interference in respiration waves.
How respiration waves and parameters are displayed.
How to configure respiration settings like apnea delay and wave gain.
How to set up respiration-related alarms.
Introduction to Pulse Rate (PR) measurement.
How Pulse Rate (PR) is displayed on the monitor.
How to set the volume for Pulse Rate (PR) sounds.
How to set up PR-related alarms.
Introduction to SpO2 (blood oxygen saturation) measurement.
Safety precautions for SpO2 monitoring.
Steps for performing SpO2 monitoring.
How SpO2 parameters and waves are displayed.
How to configure SpO2 settings like wave speed and mode.
Factors that can affect SpO2 measurement accuracy.
How to set up SpO2-related alarms.
Introduction to Non-Invasive Blood Pressure (NIBP) measurement.
Safety precautions specific to NIBP measurement.
Limitations and conditions affecting NIBP measurement.
Steps for performing NIBP measurements.
How NIBP measurement results are displayed.
How to manually set the initial cuff inflation pressure.
How to reset NIBP pump settings.
Procedures for cleaning and disinfecting the NIBP cuff.
How to set up NIBP-related alarms.
Introduction to temperature measurement.
Safety precautions for temperature measurement.
Steps for performing temperature measurements.
Requirements for accurate temperature measurement.
How temperature measurements are displayed.
How to set the temperature unit (°C or °F).
How to set up temperature-related alarms.
Technical details for temperature measurement.
How to view trend data in a graphical format.
How to view trend data in a tabular format.
How to review past NIBP measurements.
Introduction to the monitor's battery system and status indicators.
Guidelines for proper battery usage and maintenance.
How to check the battery's performance.
Information on proper battery disposal and recycling.
General guidelines for caring for the device.
Procedures and recommended agents for cleaning the monitor.
Procedures for disinfecting the monitor.
Basic checks to perform before using the monitor.
How to check the monitor's software version.
Scheduled maintenance tasks and their frequencies.
Procedure for calibrating the ECG signals.
Safety classifications for the BT-770 monitor.
Details on physical characteristics, display, audio, and alarm signals.
Details functional specifications for ECG, TEMP, RESP, NIBP, and SpO2.
Lists physiological alarms, their causes, and countermeasures.
Lists technical alarms, their causes, and countermeasures.
Information on electromagnetic emissions compliance.
Guidelines for separation distances from RF equipment.
Information on electromagnetic immunity compliance.