Operating instructions iS10 / iS20 IXNET dialogs
38019417000 en 67
7
<SOH>0<ETX>254<ETX>001<ETX>I?LV01|RX01|LX02<CR><LF>
Start character: 0x01 <SOH> (cannot be changed)
TYPE: 0x30 0 (cannot be changed)
Separators: 0x03 <ETX> (can be changed via step
73)
SCR: 0x32, 0x35, 0x34 254 (cannot be changed)
Separators: 0x03 <ETX> (can be changed via step
73)
DEST: 0x30, 0x30, 0x31 001 (cannot be changed)
Separators: 0x03 <ETX> (can be changed via step
73)
IXData: 0x49, 0x3F, 0x4C, 0x56, 0x30, 0x31, 0x7C, 0x52,
0x58, 0x30, 0x31, 0x7C, 0x4C, 0x58, 0x30, 0x32
I?LV01|RX01|LX02
End character: 0x0D <CR> (cannot be changed)
End character: 0x0A <LF> (cannot be changed)
LRC: deactivated
7.2 Data dialog IXNET interface
Default settings in PC/EDP parameter menu
Step 70 24
Step 71 9600
Step 72 n8
Step 73 03
Step 74 1
Possible commands
GV05
Machine information
GX01
Reset
GX02
Zero setting
GX05
Tare
GX06
Deleting tare
RX01
Weight request without stability evaluation
RX02
Weight request with stability evaluation
RX03
Item recording, non-adding
RX04
Item recording, adding
RX07
Total recording