500 E Global Operating Instructions
Initial operation
3
; Check the tightness of the hose connections and the condition of
the hose to the filter.
; Make sure the dust container of the filter unit is empty.
; Check the separator parts for wear and defects. Remove foreign
bodies and dust deposits in order to prevent the separator from
being blocked.
; Check the electrical connections for dirt and foreign body
deposits.
; Check the electrical motors for dirt and other contaminants.
; Check the level of abrasive in the storage hopper. Refill if
necessary.
Before start-up the operating personnel must be familiar with the
safety regulations given in this manual.
; Check the main power cable and the dust hose for damage.
Replace or repair all damaged parts before starting the machine.
; Connect the blast cleaning machine and the filter unit with the
dust hose. Use hose clamps at the connections.
; Connect the supply cable of the blast cleaning machine with
filter unit. Connect the electric cable of the filter unit with the site
supply (400-480 V, 60 Hz, 63 A).
; Make sure that the side seals are positioned correctly in the side
seal boxes (see Chapter 3.12).