737 Operations Manual
Non-Normal Checklists -
Engines, APU
Copyright © The Boeing Company. See title page for details.
NNC.7.22 D6-27370-400E-TBCE
POWER MANAGEMENT CONTROL
(PMC) INOPERATIVE
Condition: The power management control INOP light
illuminated indicates the PMC is inoperative or OFF.
THRUST LEVERS (if required) . . . . . . . . . . . . . . . . . . ADJUST
Flight may continue with the autothrottle ON.
In manual operation, adjust the thrust levers as required.
Observe engine limits.
REVERSER
Condition: The REVERSER light illuminated indicates a fault is
detected in the related engine reverser system.
Note: Additional system failures may cause inflight
deployment.
Expect normal reverser operation after landing.