EasyManua.ls Logo

Boeing 737 - NNC.8 Non-Normal Checklists-Fire Protection; AIR CONDITIONING SMOKE;FUMES

Boeing 737
434 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
737 Operations Manual
Non-Normal Checklists -
Fire Protection
Copyright © The Boeing Company. See title page for details.
D6-27370-400E-TBCE NNC.8.1
NNC.8 Non-Normal Checklists-Fire Protection
AIR CONDITIONING SMOKE/FUMES
Condition: A concentration of air conditioning smoke/fumes is
identified.
OXYGEN MASKS AND SMOKE GOGGLES
(if required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ON
CREW COMMUNICATIONS
(if required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ESTABLISH
RECIRCULATION FAN SWITCH(ES) . . . . . . . . . . . . . . . . . .OFF
[Eliminates possible source of smoke/fumes.]
If smoke/fumes stop:
Continue flight with the recirculation fan switch(es) OFF.
If smoke/fumes continue:
ISOLATION VALVE SWITCH . . . . . . . . . . . . . . . . . . . CLOSE
R PACK SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OFF
If smoke/fumes stop:
Continue flight with the R PACK switch OFF and
ISOLATION VALVE switch CLOSE.
If smoke/fumes continue:
R PACK SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . AUTO
L PACK SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OFF
If smoke/fumes stop:
Continue flight with the L PACK switch OFF and
ISOLATION VALVE switch CLOSE.
If smoke/fumes continue:
L PACK SWITCH. . . . . . . . . . . . . . . . . . . . . . . . . AUTO
Plan to land at nearest suitable airport.
Accomplish the SMOKE/FUMES REMOVAL checklist, if
required.
June 08, 2001

Table of Contents