737 Operations Manual
Non-Normal Checklists -
Fire Protection
Copyright © The Boeing Company. See title page for details.
NNC.8.4 D6-27370-400E-TBCE
ELECTRICAL SMOKE/FUMES OR FIRE
Condition: Electrical smoke/fumes/fire is identified.
OXYGEN MASKS AND SMOKE GOGGLES
(if required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ON
CREW COMMUNICATIONS
(if required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ESTABLISH
RECIRCULATION FAN SWITCH(ES) . . . . . . . . . . . . . . . . . .OFF
[Removes fan as a possible source of smoke/fumes. Stops recirculation of
smoke/fumes and increases fresh air flow.]
If smoke/fumes/fire source is known:
ELECTRICAL POWER
(affected equipment). . . . . . . . . . . . . . . . . . . . . . . .REMOVE
If practical, remove power from affected equipment by
switch or circuit breaker in flight deck or cabin.