Safety Instructions
16
1070 073 822-104 (02.06) GB
Observe the following protective measures for electrostatically sensitive de-
vices (ESD)!
D The personnel responsible for storage, transport and handling must be
trained in ESD protection.
D ESDs must be stored and transported in dedicated protective packaging.
D Out of principle, ESDs may be handled only at special ESD work stations
equipped for this particular purpose.
D Personnel, work surfaces and all devices and tools that could might come
into contact with ESDs must be on the same potential (e.g., earthed).
D An approved earthing wrist strap must be worn. It must be connected to
the work surface via a cable with integrated 1 MW resistor.
D ESDs may under no circumstances come into contact with objects sus-
ceptible to accumulating an electrostatic charge. Most items made of
plastic belong to this category.
D When installing ESDs in or removing them from an electronic device, the
power supply of the device must be switched OFF.