Maintenance and Replacement
813
1070 073 822-104 (02.06) GB
Arrangement of expansion slots in the housing
ISA slot A5
ISA/PCI slot A1
PCI slot A2
PCI slot A3
PCI slot A4
ISA slot A6
Slot cover
If the card is Plug-and-Play (PnP) compatible, it is automatically recognized
and integrated in the system, provided this creates no hardware conflicts
(IRQ, etc.) with other expamnsion cards or connected devices.
In the event that subsequent to a system reboot the functions based on the
newly aded card are not available, there may be several reasons for this:
D The card is not properly seated in the PCI or ISA slot contacts.
D The software driver for the card has not been installed or its installation is
faulty.
D IRQ (interrupt) conflict with other PC hardware components.
D The software for the card has not been installed.
CAUTION
Destruction of main board or ISA cards through address conflicts
(IRQ, memory access, I/O address)!
Observe the information provided by the card manufacturer. You
may have try out new configuration settings in both BIOS and operat-
ing system.