Access Controller AMC-4W Description of the AMC-4W
- Power supply for internal electronics: 10V - 35V DC
- Power supply for peripherals: 12V DC
- The AMC-4W is to be used with power supply Deutronic E-TOP60-12 or
Altronix AL600ULX
- Optional uninterruptible power supply Deutronic D-TOP-BAT-LCB 12-12
or Altronix AL600ULX
- The AMC-4W is to be used with mounted enclosure only
3.3. System Overview
The Access Controller AMC-4W is connected between the management host
system and different peripheral devices.
Figure 6: System overview
By default a management host system is connected via Ethernet. A
management host connection via RS485 or RS232 is also possible.
In RS485 mode up to eight access controllers AMC-4W can be combined on
one party line. Via Wiegand interfaces up to four peripheral devices can be
connected to each AMC-4W.
Bosch Security Systems | V.3.1/2006-09 Installation Guide 17