Access Controller AMC-4W Installing the AMC-4W
Bosch Security Systems | V.3.1/2006-09 Installation Guide 37
Caution! Risk of Damage!
Do not connect externally powered devices in wet mode This can
damage the AMC-4W.
Caution! Risk of Damage!
Do not exceed switching specifications of the relay. Using exceeding
voltage or current on relay contacts in either mode can damage the
AMC-W.
Figure 25: Location of the relay output connectors
A complete connection diagram of the relay output connectors is
shown in chapter 7.1 ‘Connecting Diagram’ of this documentation.
Each relay output has a separate jumper setting on the bottom side of the lower
circuit board to activate wet or dry mode.
Figure 26: Location of relay output jumpers (bottom side)