D7212GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 59
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
User Cmd 9
Default: P
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
24
User COMMAND
9
[COMMAND][9]
Use this function to activate an alarm programmed in
COMMAND 9 in the POINTS > Command 7 /
Command 9 section.
Bypass a Point
Default: P
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
25 Bypass a Point [COMMAND][0]
Use this function to bypass individual points that have
P## Bypassable enabled. Points within the scope of
the keypad can be bypassed where the function is
entered (refer to Section 2.9.1 Keypad (Command
Center) Assignment) on page 44.
The control panel ignores alarms and troubles, and
does not display point faults when a point is
bypassed.
Unbypass a Point
Default: P
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
26 Unbypass a Point [COMMAND][0][0]
Use this function to unbypass individual points that
are programmed either P## Force Arm Returnable
or P## Bypass Returnable. Points within the scope
of the keypad can be unbypassed where the function
is entered (refer to Section 2.9.1 Keypad (Command
Center) Assignment) on page 44. The control panel
responds to alarms and troubles, and displays point
faults when a point is unbypassed.
Reset Sensors
Default: E
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
27 Reset Sensors [COMMAND][4][7]
Use this function to activate the Reset Sensors
function for Fire or Intrusion points programmed as
P## Resettable in Section 4.1 Point Index on page
77. Points within the scope of the keypad where the
function is entered reset. Refer to Section 2.9.1
Keypad (Command Center) Assignment on page 44.
Change Relay
Default: P
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
28 Change Relays [COMMAND][5][4]
Use this function to manually set and reset Relays 1
through 24 that are installed in the system.
Remote Program
Default: P
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
29
Remote
Programming
[COMMAND][4][3]
Use this function to start remote programming
software (RPS) sessions. When the phone is ringing
at the control panel, starting this function causes the
control panel to seize the line.
Move to Area
Default: P
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
30 Move to Area [COMMAND][5][0]
Use this function to switch the keypad’s assignment
temporarily to a different area. This command can be
used to perform any function that can be performed
by a keypad assigned to the area in programming.
Users are limited to performing functions enabled by
the authority level they have in the area to which the
keypad is moved. After 15 sec of no activity at the
keypad, the keypad reverts back to the originally
programmed area.