140/176 Web interface
Bosch Rexroth AG, MIT: ID 40, 3 842 530 344/2014-05
10.5.3 MDT register page
The View area of the MDT register data field contains the current values in
hexadecimal format to the right of the register names in gray.
Modify individual registers by selecting the desired MDT register in the Set selection
field, entering the corresponding value in the Value field and entering it in the MDT
by selecting Set MDT Register.
The following MDT registers can be modified:
MDT status: entering any value resets the MDT
MDT counter: the MDT counter is set to the entered value
SLK operative flag
Auto mode
All Look Ahead Control registers
The value ranges and how the SLK registers function are described in Chapter 4.2.3
“MDT register area”.
The MDT register values are automatically updated after the values are changed.
The “Status” field shows the result of the write access. If no MDT is in the
CONNECTED link state, the error message BAL_RV_COM_ERR appears.