26/176 Installing MDT and SLK
Bosch Rexroth AG, MIT: ID 40, 3 842 530 344/2014-05
3.4.2 Connecting the fieldbus
The fieldbus is connected through the corresponding Bus In and Bus Out M12
sockets. The mechanical coding of the plugs largely prevents any confusion.
Fig. 11:
BUS OUT
BUS IN
Bus terminal
Connecting the ID 40/SLK to the fieldbus
For nearly all fieldbus systems, a bus connection has to be inserted in Bus Out when
the SLK is the last bus user.
Do not forget the bus connection on the last user, otherwise the entire bus will
not function.
For Interbus, the bus connection can also be configured through a serial interface. In
this instance, insert the included cap in the Bus Out socket to ensure the protection
class.